Loose tube stranded cable with aluminum tape non-armored PE sheath (GYTA).
Manufacturer: Nanjing Wasin Fujikura
Cable Construction
Loose tubes surround a central steel wire, with aluminum tape and a polyethylene sheath around the core.
Operating Conditions
- Operating temperature: -40 °C to +70 °C
- Bending radius: static 10 × D; dynamic 20 × D (D is cable diameter)
Technical Specifications
Values and units are based on information published by the manufacturer.
| Fiber count | Nominal diameter (mm) |
Nominal weight (kg/km) |
Max fiber per tube | NO.OF(Tubes +filler) | Allowable tensile load (N) (short term/long term ) |
Allowable crush resistance (N/10cm) (short term/long term ) |
| 2~30 | 9.7 | 90 | 6 | 5 | 1500/600 | 1000/300 |
| 32~36 | 10.3 | 109 | 6 | 6 | 1500/600 | 1000/300 |
| 38~60 | 10.8 | 119 | 12 | 5 | 1500/600 | 1000/300 |
| 62~72 | 11.5 | 145 | 12 | 6 | 1500/600 | 1000/300 |
| 74~96 | 13.5 | 175 | 12 | 8 | 1500/600 | 1000/300 |
| 98~120 | 14.8 | 209 | 12 | 10 | 1700/600 | 1000/300 |
| 122~144 | 16.6 | 249 | 12 | 12 | 2000/600 | 1000/300 |
| 146~216 | 16.7 | 254 | 12 | 18(2 layers) | 2000/600 | 1000/300 |
| 218~288 | 19 | 325 | 12 | 24(2 layers) | 2500/600 | 1000/300 |
Additional technical details
The optical fibers are housed in high-modulus plastic loose tubes, with water-resistant filling inside and outside the tubes. Tubes and fillers are stranded around a high-modulus corrosion-resistant phosphated steel wire, optionally coated with polyethylene, to form a compact circular core. Plastic-coated aluminum tape is wrapped around the core. An outer polyethylene sheath is extruded over the core. Full-section water blocking and tube gel protect against moisture; flexible tubes are easy to route in closures, and the cable provides mechanical and temperature performance. The jacket protects against UV, fungus, abrasion and other environmental factors. The manufacturer states a service life above 30 years with controlled production and materials. For long-distance and building communications, installed in ducts or aerially; operating temperature −40 to +70 °C; bending radius 10 × diameter static and 20 × dynamic.